Case Study

Pump refurbishment and coating



Refurbishment and coating of a five-stage p10 accelerator pump.

Client

Major oil & gas operator.

 

Scope of Work 

  • Pump received in parts, following strip and wash to remove LSA scale.
  • Wetted areas pre and post-machined. Coated using Corroglass 600 Series.
  • Assembled and checked for free rotation.
  • Pressure tested @80 psi for 30 minutes.

 

Products   

 

Coating System

Internals

  • Grit blasted internally to ISO 8501- Cleanliness Standard Sa 2½
  • Coated internally using Corroglass 600 Series to a minimum 1.25mm DFT.
  • Thickness checked. Spark tested at 16kv

External 

  • Grit blasted externally to ISO 8501-1 – Cleanliness Standard Sa 2.
  • Applied two coats of Plasmet ZF with a topcoat of Corrothane AP1.

 

Inspection Report 

Pump was received in parts following strip and wash to remove LSA. Drawings and instructions regarding reassembly were not available. Following several trial assemblies, Corrocoat’s engineering team were able to identify the mode of operation for the pump.

Pump Impellers - The Five Stage Pump Casing - Assembled Pump

Visit Our Other Sites