Oil & gas industry, UK.
First application – 1983.
Maintenance review – 2004.
Maintenance work to clean, inspect, touch up minor
mechanical damage externally, and recoat flange areas.
Polyglass Standard for original coating in 1983.
Corroglass 600 Series for repair work in 2004.
Steel.
• Flash blast the existing coating. Grit blast damaged flange areas to ISO 8501-1, cleanliness standard SA 21/2 with minimum surface profile of 50μm.
• Apply Corroglass 600 Series to a min.dft of 1.5mm.
• Thickness check and spark test to 19Kv Hv-AC.
These seawater pump riser pipes first came to Corrocoat 21 years ago, and were protected internally and externally with the original Polyglass Standard product.
During the service life, which comprised external exposure to seawater (immersed, splash zone and atmospheric), and internally, seawater with a low
hydrochlorite dosing (4%), the coating has not shown any tendency to undercut, and only minor mechanical damage was needed to be repaired.
The sustained performance of Polyglass Standard under adverse operating conditions demonstrates the products’ suitability for use in diverse applications
throughout industry.