Major oil & gas operator.
August 2007.
Pump received in parts, following strip and wash to remove LSA scale.
Wetted areas pre and post-machined.
Coated using Corroglass 600 Series.
Assembled and checked for free rotation.
Pressure tested @ 80 psi for 30 minutes.
Corroglass 600 series.
Plasmet ZF.
Corrothane AP1.
Cast steel.
Grit blasted internally to ISO 8501- Cleanliness Standard
SA 21/2.
Coated internally using Corroglass 600 Series to a
minimum 1.25mm DFT.
Thickness checked. Spark tested at 16kv.
Grit blasted externally to ISO 8501-1 – Cleanliness
Standard SA 2.
Applied two coats of Plasmet ZF with a topcoat of
Corrothane AP1.
Pump was received in parts following strip and wash to remove LSA. Drawings and instructions regarding reassembly were not available. Following several trial
assemblies, Corrocoat’s engineering team were able to identify the mode of operation for the pump.
Accelerator Pump Refurbishment & Coating of a Five-Stage p10